The Visible Pen is used to check or identify singlemode and multimode optical fibers & components. The universal adapter is suitable for every 2.5 mm or 1.25 mm fiber optic connector. The small, compact and handy housing makes the device suitable for daily use.
Specifications:
Parameter | Value |
---|---|
Wavelength | 630 - 680 nm |
Output power singlemode | ≥ 0.3 mW |
Output power multimode | ≥ 1.0 mW |
Distance | up to 5 km |
Operation Mode | CW, Pulse, ON/OFF |
Laser Class | 3R |
Dimensions length | 168 ± 2 mm |
Dimensions diameter | 13.5 mm |
Batteries | Alkaline AAA, 2 pcs |
Suitable fiber optic connectors VSP-03-250 | E2000, FC, SC, ST, LSA, standard 2.5 mm ferrule |
Suitable fiber optic connectors VSP-03-125 | LC, MU, LX5, SFF 1.25 mm ferrule |
Operating Temperature | -10 °C to +50 °C |
Storage Temperature | -40 °C to +70 °C |
Inserting the batteries: Unscrew the cover and insert batteries (3) with the correct polarity. The correct polarity is shown in the drawing.
Operation: The instrument can be switched on and off by pressing the button (1). By repeatedly pressing the button (4) the operator can select between a continuous light mode, flashing mode with approximately frequency 3 Hz and ON/OFF mode. Signalization LED (2) shows the selected mode. Then the laser beam will emerge from the outlet.
Safety Notes:
- Never look into the laser beam and do not point it at humans or animals. Laser radiation can cause damage to the eyes or skin.
- Do not point the laser pointer at a mirror or other reflecting surfaces. The uncontrolledly deflected beam can hit humans or animals.
- The device and the batteries are not for children. They are not a toy.
- The product is equipped with a class 3R laser product.