The OPTOKON OMK-SR-OTS.2 Diagnostic Set (hereinafter referred to as the "set") is designed for diagnosing fiber-optic lines in tactical or industrial network environments with HMA connectors.
Includes:
- LS-800 light source;
- PM-800 optical power meter (or equivalent);
- hard case, adapters, HMA / FC patch cords, HMA-HMA, USB cable, etc.
The set is designed for field use: shock-resistant case (Peli 1450), IP67 protection according to EN60529/IEC60529 standards.

Main applications:
- Measuring losses (insertion / return loss) in fiber lines;
- Checking connectors, splitters, adapters;
- Mobile diagnostics during network installation/maintenance.
Main specifications


LS-800 Light Source
- Compact size, lightweight.
- Modulation: CW, 270 Hz, 1 kHz, 2 kHz.
- AWD (Auto Wavelength Detection) function – automatic wavelength recognition.
- Interchangeable output connectors (FC, SC, ST, LC/PC, LC/APC) and adapters.
- Wavelength range: 850 nm, 1300 nm, 1310 nm, 1490 nm, 1550 nm, 1625 nm, and visible 650 nm.
- Power supply: 3 × AA batteries or USB charging.
PM-800 Power Meter
- Compact, lightweight design.
- Measurement of absolute and relative optical power.
- Support for multiple wavelengths.
- Data memory (results recording), USB port for download – SmartProtocol PC.
- Power supply: 3 × AA or USB.
Package contents
- Peli 1450 hard case (IP67, MIL-STD MIL-C-4150j).
- Patch cords: HMA / FC, HMA-HMA (see Technical Data).
- Adapter a-FC / PC-02-240-12, USB cable, connector cleaner (CLETOP-A), certificates, manuals.
Comparative specifications
Parameter | LS-800 Light Source | PM-800 Power Meter |
Wavelengths | 850 nm, 1300, 1310, 1490, 1550, 1625, 650 nm (visible) | Support for multiple wavelengths (depends on configuration) |
Modulation / Functions | CW/270 Hz/1 kHz/2 kHz modulation; AWD function | Auto wavelength detection (AWD); memory; USB |
Power supply | 3 × AA batteries / USB charging | 3 × AA / USB charging |
Case / Protection | Part of the set with Peli case, IP67 | Similar design in a case, adapted for field conditions |
Purpose | Reliable signal source for loss testing | Measurement and analysis of optical power and losses |
Features of OMK-SR-OTS.2
- Fully complete "turnkey" set – no need to purchase a light source or meter separately.
- Designed for HMA connectors (commonly used in military/tactical environments) – specialized HMA-FC and HMA-HMA adapters.
- High level of case protection (IP67, shock-resistant case) allows operation in field and harsh conditions.
- AWD (automatic wavelength selection) minimizes operator errors.
- USB interface for data transfer to PC allows report generation and documentation.
- Suitable for both installation and maintenance of fiber-optic networks.
Advantages
- Versatility: covers a wide range of wavelengths, interchangeable adapters, compatibility with various connectors.
- Compactness and mobility: the entire set fits in a case – convenient for field trips.
- Reliability: climate/shock-resistant case, field-ready.
- Convenience features: AWD, USB connection, data recording.
- Specialization for HMA / FC – an advantage for specific applications (military, tactical networks).

FAQ (Frequently Asked Questions)
Q1: Which networks is this set suitable for?
A: It is suitable for fiber-optic networks (both multimode and single-mode), especially when HMA connectors are used and field diagnostics are required.
Q2: Can losses be measured on two wavelengths simultaneously?
A: Yes – the LS-800 source supports multiple wavelengths (e.g., 1310 nm and 1550 nm) and has AWD function, making measurement easier.
Q3: Can a computer be connected for report generation?
A: Yes – the PM-800 meter has a USB interface, data recording, and compatibility with SmartProtocol software.
Q4: What warranty or service is provided?
A: The manufacturer states that the company is ISO 9001 certified and has an accredited calibration laboratory.
Q5: Is separate calibration required?
A: Yes – for accurate measurements, ensure devices have a current traceable calibration certificate. The set also includes accessories for connector cleaning.
Q6: Can it be used for a home FTTH network?
A: Technically yes, but the set may be excessive in functionality and cost. If the network uses standard connectors (LC/SC) and is low-demand, a simpler tester can be chosen.